Description

Infrared thermometers are temperature sensing devices that use electromagnetic radiation to make non-contact surface temperature readings. Infrared thermometers, sometimes called pyrometers, are widely used throughout many industries and environments. They are especially useful for applications in which quick spot temperature readings are desired or where conventional temperature sensors cannot be easily used.

Thermometers can be classified as either contact or non-contact. Contact thermometers, as the name implies, must touch the target to determine its temperature. The bulb thermometer hanging outside, for instance, measures air temperature by being in direct contact with the air. Bimetal thermometers and those that use thermocouples and RTDs are all examples of contact thermometers. Contact thermometers are inexpensive and accurate, making them the most prevalent type of thermometer in temperature measurement.

Contact thermometers, however, have limitations. They often take time to “come up to temperature” making them more suitable for fixed mounting to constantly monitor temperature than for quick spot-checking of temperature. Inadequate space, distance, moving targets, or environmental conditions may also restrict their ability to contact the medium. These situations are where infrared thermometers excel.

Applications for Infrared Thermometers

Infrared thermometers are highly versatile making them indispensable tools in the technician’s toolbox. They can be employed anywhere at any time. Some common applications include:

  • Checking mechanical equipment for hot spots that may be a sign of impending failure
  • Inspecting electrical panels, circuit breakers and outlets for hot spots
  • Checking heater or oven temperature, for calibration and control purposes
  • Detecting hot spots / performing diagnostics in electrical circuit board manufacturing
  • Checking for hot spots in firefighting situations
  • Monitoring materials in process of heating and cooling, for research and development or manufacturing quality control situations
  • Identifying hot/cool spots during home inspection to find drafts or to determine if insulation is adequate
  • Checking temperatures as part of auto maintenance

How Infrared Thermometers Work

Infrared radiation is one of many forms of electromagnetic energy and consists of wavelengths of energy just longer than those of visible light. Infrared, like visible light, infrared can be focused, reflected or absorbed.

All matter above absolute zero constantly emits infrared energy due to the natural vibration of molecules. This vibration, and the corresponding infrared energy, is proportional to the temperature of the matter—the warmer the matter, the more vibration and the more infrared energy emitted.

Infrared thermometers use a lens to focus infrared energy emitted from an object onto a detector, called a thermopile. The detector, in turn, converts that energy into an electrical signal which, after compensating for the ambient temperature, is displayed in units of temperature. Filtering and signal processing amplifies and stabilizes the signal for more accurate and linear readings.

Specifications and Features of Infrared Thermometers

As with most instruments, infrared thermometers are available in a range of styles with specifications suited to one’s budget and needs. Some of the most common specifications and features include:

Emissivity: Emissivity refers to the ability of a material to emit thermal radiation. All materials absorb, reflect and emit radiant energy. Certain materials, however, are better at doing this than other materials. Emissivity, therefore, is the ratio of the radiation emitted by a surface of a material to the radiation emitted by a blackbody, both a perfect absorber and emitter of energy, at the same temperature. All radiation absorbed by a blackbody will also be emitted by it. Blackbodies therefore have an emissivity of 1.0. Dark materials with a rough surface generally have a high emissivity. Asphalt for example has an emissivity of 0.90 meaning that it absorbs and emits 90 percent of radiant thermal energy and reflects only 10 percent.

The bottom end of the emissivity scale would be the perfect reflector which reflects, rather than absorbs, all radiation. The emissivity of this theoretical surface would be 0.0. Bright, glossy materials generally have a low emissivity. Aluminum foil, for example, has a thermal emissivity value of 0.03, meaning it absorbs and emits only 3 percent of radiant thermal energy while reflecting 97 percent. Obtaining an accurate measurement on low emissivity materials can be very challenging.

Although some basic models of infrared thermometers have fixed emissivity, many have adjustable emissivity settings that can be determined by the user. Emissivity tables provide standards for common materials allowing users to adjust settings for models with such capability.

Distance-to-spot ratio: The distance to spot ratio, usually abbreviated as D:S, refers to the size of the measurement area (spot) when the device is held at a certain distance from the target. For instance, a unit with a 20:1 D:S ratio will produce a 1” diameter measuring spot when held 20” from the target, or 2” spot when held 40” away. This is important since the spot is an area over which temperatures are averaged. If the actual target is very small, it is best to have a unit with a higher ratio so as not to risk inaccurate measurements by including areas not targeted in the measurement. Calculating the spot size using the D:S ratio may be misleading for close focus units or those involving long distances

Spectral range: Infrared light consists of wavelengths from 0.7 to 1000 μm. Spectral range refers to the specific range of wavelengths captured by an infrared thermometer. Most infrared thermometers operate under 20 μm. This is due to both cost efficiency as well as the negative effects on accuracy caused by the atmosphere on longer wavelengths.

Laser sight: Laser sights are often found on infrared thermometers. Their only function is to help aim the unit. The actual measurement area is larger than the red dot.

Fixed vs handheld: Most imagers are handheld, making them ideal for spot checking temperatures for maintenance, troubleshooting, or inspection. Some, however, are designed to be fix mounted as part of a process application. There are a wide range of outputs available to integrate into a control system.

Additionally, infrared thermometers can include a number of other such as communications, data logging, ingress protection, and others.

Things to consider when selecting an infrared thermometer:

  1. Should the unit be handheld or fixed?
  2. What is the target size and distance?
  3. What type of surface is being measured?
  4. What is the required temperature range?
  5. What is an acceptable level of accuracy?
  6. What is the ambient environment?
  7. Are data logging or communications needed?
  8. What are the output requirements?

Corporate Station Bangladesh is a professional supplier of Infrared Thermometer in Bangladesh. To Know more about Infrared Thermometer in BD contact with Corporate Station Bangladesh anytime.